Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 38(1): 197-203, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37792140

RESUMO

To identify and prevent perioperative hypothermia, most surgical patients require a non-invasive, accurate, convenient, and continuous core temperature method, especially for patients undergoing major surgery. This study validated the precision and accuracy of a cutaneous zero-heat-flux thermometer and its performance in detecting intraoperative hypothermia. Adults undergoing major non-cardiac surgeries with general anaesthesia were enrolled in the study. Core temperatures were measured with a zero-heat-flux thermometer, infrared tympanic membrane thermometer, and oesophagal monitoring at 15-minute intervals. Taking the average value of temperature measured in the tympanic membrane and oesophagus as a reference, we assessed the agreement using the Bland-Altman analysis and linear regression methods. Sensitivity, specificity, and predictive values of detecting hypothermia were estimated. 103 patients and one thousand sixty-eight sets of paired temperatures were analyzed. The mean difference between zero-heat-flux and the referenced measurements was -0.03 ± 0.25 °C, with 95% limits of agreement (-0.52 °C, 0.47 °C) was narrow, with 94.5% of the differences within 0.5 °C. Lin's concordance correlation coefficient was 0.90 (95%CI 0.89-0.92). The zero-heat-flux thermometry detected hypothermia with a sensitivity of 82% and a specificity of 90%. The zero-heat-flux thermometer is in good agreement with the reference core temperature based on tympanic and oesophagal temperature monitoring in patients undergoing major surgeries, and appears high performance in detecting hypothermia.


Assuntos
Hipotermia , Termometria , Adulto , Humanos , Temperatura Corporal , Temperatura , Temperatura Alta , Monitorização Intraoperatória/métodos , Termômetros , Esôfago
2.
Bing Du Xue Bao ; 28(3): 258-64, 2012 May.
Artigo em Chinês | MEDLINE | ID: mdl-22764529

RESUMO

ENHANCIN is an enhancing protein chiefly found in insect baculoviruses. One ENHANCIN homologue was identified, by blast method, in Agrotis Segetum granulovirus (AgseGV) genome, named enhancin-like. Sequence analysis indicated that this gene includes the conserved domains, conserved in other ENHANCIN, and it has no signal peptide or a-transmembrane helix. A proline-rich domain, which is similar to those of mammals, is present at its C-terminal. To analyze the synergistic function of AgseGV enhancin-like gene, prokaryotic expression vectors of its whole gene and the 5'-truncated fragment (1, 017bp) were constructed. Expression product of truncated fragment was purified by chromatography, and then it was used to prepare antibody. The expression product of whole gene was identified by Western blot with specific antibody and anti-His-Tag antibody. Bioassay proved that the expression product of whole gene can increase the mortality with 16.25% to 3th instar larvae of Helicoverpa armigera (HaNPV: 1.17 x 10(2) PIBS/mL), while the truncated fragment has no obvious synergistic function.


Assuntos
Baculoviridae/metabolismo , Expressão Gênica , Proteínas Virais/genética , Proteínas Virais/metabolismo , Sequência de Aminoácidos , Animais , Baculoviridae/genética , Controle de Insetos , Larva/efeitos dos fármacos , Larva/crescimento & desenvolvimento , Dados de Sequência Molecular , Mariposas/efeitos dos fármacos , Mariposas/crescimento & desenvolvimento , Controle Biológico de Vetores , Proteínas Virais/isolamento & purificação , Proteínas Virais/toxicidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...